Ultrasonic level switch
Ultrasonic level switch
Non-Invasive-Ultrasonic Liquid Level Transmitter 6
Ultrasonic level switch
Ultrasonic level switch
Ultrasonic level switch
Ultrasonic level switch
Non-Invasive-Ultrasonic Liquid Level Transmitter 6
Ultrasonic level switch
Ultrasonic level switch

Ultrasonic Level Switch/Controller

The external ultrasonic level switch is a new type of liquid level monitoring and alarm instrument. The high-frequency ultrasonic pulses generated by the level controller probe can penetrate the tank wall. And ultrasonic pulses transmit between the tank wall and the liquid and reflect back. By calculating the reflection behavior, the level switch can identify whether there is liquid at the monitored position. The level switch can also send relay signals to subsequent devices or other devices to achieve the function of synchronous monitoring.

  • Advanced signal processing method
  • Overcome the influence of temperature drift
  • Stronger anti-interference
  • Easy to install
  • New installation method: adsorption + adhesive
  • Probe works stably
  • Built-in temperature sensor
  • Adjustable
  • Probe status detection and software upgrade are available.

Introduction of Ultrasonic level switch

The ultrasonic level switch is suitable for monitoring the liquid level in the tank and issuing an alarm when the liquid level reaches the highest or lowest level. It can also be used to identify the presence of liquid in the pipeline (dry protection). The tank body can be made of various metals, non-metals or non-foamed plastics. This measurement technology is not affected by medium density, dielectric constant, conductivity, reflection coefficient, pressure, temperature, precipitation or other factors. Therefore, it can be used for level control of various liquids in the pharmaceutical, petroleum, chemical, electric power, food and other industries. And it is an ideal choice for detecting dangerous, toxic or corrosive liquids.Ultrasonic level switch

Technical parameters of Ultrasonic level switch

Model Basic type Pro type
Item Ordinary explosion-proof type; two-point monitoring explosion-proof type;

intrinsically safe type; two-point monitoring intrinsically safe type;

Accuracy ±2mm
Measurable wall thickness max 70mm
Output signal Liquid level alarm Available in 3 basic types
error alarm 485 signal MODBUS
4- 20mA (only intrinsically safe type) PROFIBUS HART
Foundation Field Bus
Relay capacity DC 30V 6A/ AC250V 6A
Power supply DC24V
Power 1W 2W
Electrical interface specifications According to actual selection and configuration
Threading hole diameter Φ8mm (adaptive cable diameter Φ6~8mm)
Explosion-proof signs Exd II CT6 Gb Exia II CT6 Ga
Shell material Cast aluminum alloy
Protection level IP67
Applicable places Other explosive gas environments except coal mines
Host applicable ambient temperature -50℃~+60℃
The host is suitable for ambient humidity 15%~100%RH
Ultrasonic probe operating temperature Ordinary type: -50℃~+80℃; High temperature type: up to 200℃
Host size 236/186*125*171.5mm 155*241*129.4mm
Host weight 2.5kg 2.6kg
Handheld meter communication distance none 3 meters
Intrinsically safe parameters Ui:28VDC   li:93Ma    Pi:0.65W  Ci:44Nf   Li:11uH
Media requirements: Pure liquid, milky liquid, suspended liquid, etc.
Container under test: Material: carbon steel, stainless steel, various hard metals, fiberglass, epoxy resin,

hard plastic, ceramics, glass, hard rubber and other materials or other composite materials.

Measurable tank types: Horizontal tanks, spherical tanks, tank tanks, vertical tanks, etc.;

Get Free Quote of Ultrasonic Level Switch

Sino-Inst has a diverse product range. This means we can meet your various measurement and control needs, thus providing a one-stop solution for many customers. Sino-Inst is customer-centric. From consulting to after-sales service, our team is committed to providing excellent support to ensure that your experience working with us adds value to your operations. Looking forward to communicating with you.

Contact Form Demo (#3)
Products Categories
Get A Free Quote
Contact Form Demo (#3)

Applications of Ultrasonic level switch

It is suitable for the measurement and control of liquid levels in various small storage tanks, process tanks, small containers, pump lifting stations, wastewater storage tanks, etc.

‌1. Petrochemical industry‌:

For example, in the oil tank area, the external ultrasonic level switch is used to monitor the liquid level of the storage tank. When the liquid level reaches the set upper limit, it can alarm in time to prevent safety accidents and economic losses. ‌ In addition, ultrasonic level switches have also been successfully used in crude oil backwash tanks in refineries to monitor the working status of filters and ensure crude oil quality. ‌

‌2‌. Pharmaceutical industry‌:

Ultrasonic level switches also have important applications in the pharmaceutical industry. Due to its non-contact measurement and high precision. It can safely monitor toxic and corrosive liquids. The aim is to avoid the safety hazards in traditional liquid level measurement methods.

3. Food Industry:

Ultrasonic level switches are used to monitor the liquid level of various liquid raw materials. It ensures the stability of the production process and product quality. Its high precision and stability make it perform well in the food industry.

4. Power Industry:

Ultrasonic level switches are used to monitor the liquid level of various water storage facilities. It ensures the normal operation and safety of power equipment. Its characteristics of not being affected by factors such as medium pressure and temperature.

Ultrasonic Level Switch Operating Environment

Measurable Tank Material:

The probe installation area on the tank wall should be a hard material with good conductivity, such as carbon steel, stainless steel, various hard metals, fiber glass, epidote, rigid plastic, ceramics, glass, rigid rubber and other composite materials. The internal and external surfaces of the installation position should be smooth. If there are multiple layers in the tank wall, the layers should be compact without foam or air gap, such as sulfide rigid rubber lining, epidote lining, stainless steel lining, and titanium.

Measurable tank wall thickness: 2-70mm

Measurable tank types: Horizontal tank, spherical tank, vertical tank, and so on.

Medium: The measurement result is not interfered with by density, permittivity, temperature, pressure, purity, or viscosity of the medium.Ultrasonic level switch

Ultrasonic level switch Video
More Detail

What is an ultrasonic level switch?

Ultrasonic level switch is a switch device that uses ultrasonic technology to detect liquid level. It can detect the liquid level height and is widely used in various industrial settings. It is usually composed of a transmitter, a receiver, an amplifier, a circuit board and a casing. When using an ultrasonic level switch, it needs to be placed above the liquid to be detected or on the outside of the tank to be detected. It is non-touching with the liquid surface.

Ultrasonic level switch

What is the difference between a level switch and a level transmitter?

‌Function and working principle

Level switch: The output signal of the level switch is usually a switch signal. There are only two states, open and closed, which is used to control the on and off of the circuit. The level switch is mainly used to control the height of the liquid level. When the measured liquid medium reaches a certain indication position, the level switch will output an alarm signal to control the continued transmission or stop of the liquid medium. For example, when the water level in the water tank rises to the full water level, the float or float touches the switch, turning on the switch and emitting a sound signal or control signal.

Level transmitter: The level transmitter emphasizes “change” and “transmission”. When the liquid level moves up and down, an electrical signal of the position is generated, but these electrical signals are usually not standard. The level transmitter converts these non-standard electrical signals into standard electrical signals (such as 4- 20mA, 0- 10V, etc.) through the circuit. The output signal of the level transmitter is a continuous electrical signal that can accurately reflect the real-time changes of the liquid level.

Application scenarios

‌Liquid level switch‌: The liquid level switch is widely used in scenarios that require simple high and low liquid level control. It is usually used to control the automatic replenishment or discharge control of liquids. Such as water tanks and oil tanks, or the start and stop of equipment such as solenoid valves and water pumps.

‌Liquid level transmitter‌: Due to its ability to output standard electrical signals, the liquid level transmitter is suitable for scenarios that require accurate measurement and remote monitoring of liquid levels, such as industrial automation control systems, environmental monitoring, drinking water systems, water level overflow weirs, pump stations, and liquid tank level measurement.

Ultrasonic level switch

Related Products

Related News

How Do You Measure Oil Flow? How to measure the flow rate of PetroChina and other high viscosity liquids in […]

What is an Ultrasonic Clamp-On Flow Meter? Ultrasonic flow meter is a non-invasive flow sensor used to measure the volume […]

7 Types of Pressure Sensors: Different Types, Working Principles, and Definitions What is a pressure sensor? A pressure sensor is […]

What is hydrostatic pressure? Hydrostatic pressure is the pressure exerted by a stationary fluid due to the effect of gravity. […]

Can pressure sensors be used to measure liquid level? Yes, it is ok to measure liquid level using a pressure […]

What Are Mass Flow and Volume Flow? Mass flowEssentially, mass flow is the mass of a gas or liquid that […]

What Is a Mass Flow Meter? A mass flow meter is a device that accurately measures the mass flow of […]

What is Heating Oil? Heating oil, also known as heat carrier oil or thermal medium oil, is a special heat […]

Scroll to Top

Get A Free Quote Now !

Contact Form Demo (#3)