Search
Close this search box.
strap-on-flow-meter
strap-on-flow-meter-structure
strap-on-flow-meter-installation
Integrated-Type-Strap-on-Flow-Meter-
strap-on-flow-meter-installation-with-connecting-cable
X3 flow meter with lora
strap-on-flow-meter
strap-on-flow-meter-structure
strap-on-flow-meter-installation
Integrated-Type-Strap-on-Flow-Meter-
strap-on-flow-meter-installation-with-connecting-cable
X3 flow meter with lora

Strap on Flow Meter | New Type Clamp-on Ultrasonic

Strap on flow meter is a NEW kind of ultrasonic clamp-on flow meter. Eeasy to install. Suitable for measuring pipe diameter Φ9.53~Φ90.

  1. The flow meter is stuck out of the pipe. No additional changes to the pipeline are required;
  2. Installation and measurement can be completed according to the operation guide without professional knowledge;
  3. No moving parts. No pressure loss. It can be installed and used without stopping production;
  4. OLED display: clear reading in dark environments
  5. Main menu and menu mode
    Easy to switch display
    Easy and quick setup
  6. Touch button
    Easy to set up and enter
  7. Reliable aviation socket, simple wiring

Strap on flow meter Description

Strap on flow meter is a new type of Clamp On Type Flow Meter.

Strap on flow meter is very unique in structural design using circular magnetic steel. Automatic snap-fit during installation. It only takes 2-3 minutes from installation to measurement. It also uses the currently popular OLED display. Easily read in low-light environments .

Strap on flow meter is widely used in production process flow measurement and monitoring. The application of the product can improve the yield rate of the product while continuously effectively and accurately controlling the flow of the fluid. Even save the input of personnel. Bring benefits to production enterprises.

Strap on Flow Meter Technical Parameters

Performance Indicators

Flow range: 0.1m/s~5.0m/s
Accuracy: +/-2.0%
Repeatability: 0.8%
Measuring pipe diameter: φ9.53~φ228(DN6~DN200)
Storage function: with daily, monthly and annual flow accumulation function
Analog output: 4-20mA, maximum load 600Ω
Alarm output: OCT upper and lower limit alarm function (option)
Communication interface: RS485, support Modbus communication protocol
Power supply: 24VDC
Cable length: 2.0 meters, can be extended
Keyboard: Four tactile keys
Display: OLED 128*64 dot matrix display
Unit: Support metric and imperial unit selection*1
Accumulator: Six-digit flow accumulator
Suitable pipe material: Steel (steel pipe), Copper (copper pipe), Plastic (plastic pipe)*2
Shell material: aluminum alloy; anti-corrosion sensor is made of PP
Ambient temperature: 0°C-50°C (32°F-122°F)
Medium temperature: Normal temperature type: 0°C-50°C (32°F-122F);
High temperature type: 0°C-120°C (32°F-248°F)
Ambient humidity: 0-95% relative humidity, non-condensing
Protection class: IP54
Note 1. Cubic Meters (m3), Liters (L), US Gallons (GAL), you can press /hour (hour), /min (minute), the factory default unit is m3/h;
Note 2. There are many kinds of plastic pipes, mainly PVC, PVDF, PPR, PFA, HDPE, etc.

Optional Types

Integrated type Integrated-type-strap-on-flow-meter
Pipe diameter: 49.53~118
(DN6-DN100)
Temperature resistance 50 degrees

 

Split type Split-Type-Strap-on-Flow-Meter
Pipe diameter: 99.53~4228
(DN6-DN200)
Temperature resistance 50 degrees
High temperature type (split) High-temperature-type-(split)-Strap-on-Flow-Meter
Pipe diameter: 49.53~(P228
(DN6-DN200)
Temperature resistance 120 degrees
Anti-corrosion type (split) Anti-corrosion-type-(split)-Strap-on-Flow-Meter
Pipe diameter: 9.53~063
(DN6-DN50)
Temperature resistance 50 degrees
PP material sensor
Special type (split) Special-type-(split)-Strap-on-Flow-Meter
Pipe diameter: 49.53, 412.7
(DN6, DN8)
Temperature resistance 50 degrees
PP material sensor
Dedicated to PFA and silicone tubing

Model Specifications

Model -9.53 -12.7 -15 -20 -25 -32 -40
Pipe outer diameter mm φ9.53 φ12.7 φ15 φ20 φ25 φ32 φ40
Nominal diameter DN DN6 DN8 DN10 DN15 DN20 DN25 DN32
Minimum outer diameter mm 9.5 12 14 20 25 32 38
Maximum outer diameter mm 11.5 13.5 16 23 30 35 45
Minimum flow I/min 0.34 0.6 0.94 1.06 1.88 2.94 4.82
Maximum flow I/min 11.02 19.59 30.62 52.99 94.2 147.19 241.15
Minimum flow rate m3/h 0.02 0.04 0.06 0.06 0.11 0.18 0.29
Maximum flow m3/h 0.66 1.18 1.84 3.18 5.65 8.83 14.47
Model -50 -63 -75 -90 -110 -140 -160 -220
Pipe outer diameter mm φ50 φ63 φ75 φ90 φ110 φ140 φ160 φ220
Nominal diameter DN DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200
Minimum outer diameter mm 48 58 72 88 108 132 158 218
Maximum outer diameter mm 54 64 78 96 116 142 168 228
Minimum flow I/min 7.54 11.78 19.9 30.14 47.1 73.59 105.98 188.4
Maximum flow I/min 376.8 588.75 994.99 1507 2355 3680 5299 9420
Minimum flow rate m3/h 0.45 0.71 1.19 1.81 2.83 4.42 6.36 11.3
Maximum flow m3/h 22.61 35.33 59.7 90.43 141.3 220.78 317.93 565.2

Get Technical Support for Strap on Flow Meter

Sino-Inst’s Strap on flow meter is an ultrasonic flow meter specially designed for small pipe measurement. It solves the problems of ordinary clamp-on flow meters being unsuitable for installation and unstable measurement on small pipe diameters.

Contact Form Demo (#3)
Products Categories
Get A Free Quote
Contact Form Demo (#3)

Strap On Flow Meter Applications

Since Strap on flow meter was put on the market, it has been widely used in the cleaning equipment industry.
Due to its simple installation and operation and reliable measurement performance, it is continuously promoted in emerging industries.

Applicable media

Strap on flow meter almost meets the requirements of different clean fluid measurements:
Mainly used in the measurement and control of water (tap water, pure water, ultrapure water). It is also suitable for various acids, alkalis, wine, chemical solvents, alcohol, drinking water, Coca-Cola water, etc.

Media measured based on user feedback:
Sulfuric acid, liquor, hydrocarbons, alcohol, sodium chlorate, sodium carbonate, triethylamine, ethylenediamine, propylene oxide, etc.

Measurable medium judgment: The medium flow in the pipeline is stable and the pressure is maintained at 0.3MPa. Bubbles (or cavitation) due to changes in flow or pressure cannot be measured.

Applicable pipe materials

Strap on flow meter can almost meet the measurement needs of pipes made of different sound-conducting materials, including “metal pipes” and “plastic pipes”.
Through menu options, the Strap on flow meter can measure both metal and plastic pipes.
Metal pipes: stainless steel pipes, carbon steel pipes, copper pipes
Plastic pipes: PVC/CPVC, PVDF, PPR, PPH, PFA/PU, HDPE, etc.

More Detail

What is ultrasonic flow meter?

An ultrasonic flow meter is an instrument that calculates the flow rate by emitting ultrasonic pulses through the fluid and measuring the propagation time of the ultrasonic waves. Ultrasonic flow meters measure the volume flow of fluids.

Signal detection principle According to the principle of signal detection, ultrasonic flow meters can be divided into propagation velocity difference method (direct time difference method, time difference method, phase difference method and frequency difference method), beam offset method, Doppler method, cross-correlation method, Spatial filtering method and noise method, etc.

What are the advantages of strap on ultrasonic flow meter?

  1. Easy to install
    External clamp-on installation, no pipe cutting required. Users simply clip the flow sensor to the pipe surface. Then the ultrasonic flowmeter can detect the flow rate through ultrasonic waves, and then automatically calculate the flow rate value, flow totalizer, etc.
  2. Wide range ratio
    Turndown ratio is a very important technical indicator in flow measurement. It is used to refer to a flow range, usually determined by the flow technology/principle.
  3. The traditional flow measurement range ratio is small, such as turbine flow meter is 10:1, orifice flow meter is 3:1, PD flow meter is 10:1, etc. However, ultrasonic flow meters are usually 100:1, and some models can reach 500:1.
  4. Low flow startup
    Strap on ultrasonic flow meter is suitable for small pipes. Very low flow measurement can be provided for process control.
  5. HVAC energy management to reduce your costs
    Ultrasonic flow meters provide advanced and accurate energy measurement and are widely used for water energy monitoring in heating ventilation and air conditioning (HVAC) management. The flow sensor is combined with the energy sensor to form an energy meter without damaging the pipe. High accuracy and stable performance helps reduce energy costs.

Related Products

Related News

Scroll to Top

Get A Free Quote Now !

Contact Form Demo (#3)