Handheld Ultrasonic Flow Meter – Portable Clamp-On, DN15 to DN6000

The Handheld Ultrasonic Flow Meter is a truly portable device designed for both mobile inspections and online monitoring. Powered by a battery, it is suitable for liquid pipelines ranging from DN15 to DN6000. It features clamp-on sensors, eliminating the need for pipe cutting or process shutdowns, and offers up to 12 hours of operation on a full charge.

Read More about: Clamp-on ultrasonic flow meter

1. Transit-time measurement, with an accuracy of up to 1%;
2. Three transducer sizes cover DN15–DN100, DN50–DN700 and DN300–DN6000; high-temperature versions go to 160°C.
3. Built-in Ni-MH battery, more than 12 hours per charge.
4. Display cumulative flow, instantaneous flow, working status, etc. at the same time.
5. Built-in data logger (2,000 lines); download over RS232 with Modbus support.

Handheld Ultrasonic Flow Meter Description

Handheld ultrasonic flow meter uses external clip-on sensing to measure liquid flow, achieving non-contact measurement of liquid flow. The sensor only needs to be installed on the outer wall of the pipe to complete the flow measurement.

During the measurement process, there is no need to destroy the pipeline, no need to stop production, the sensor does not come into contact with the measured medium, and there is no pressure loss. And it also has the characteristics of battery power supply, small size, light weight and easy to carry. It can be said that it has realized the true movable measurement of flow rate and online detection, and is a truly portable ultrasonic flow meter.

Technical Parameters of Handheld Ultrasonic Flowmeter

Basic technical parameters

Items Performance and Parameter
Main Unit Principle transit-time ultrasonic flowmeter
Accuracy 1%–2%; Repeatability: 0.2%
Display 4 line x 16 character LCD with backlight
Dimension 200 × 93 × 33 mm, 390 g
Operation Support 16 key light touch keyboard and the Simulation keyboard software
Data interface Insulate RS232 serial interface, upgrade the flow meter software from a PC,
support the MODBUS, etc.
Signal Output 1 way OCT output
Shell material Flame retardant ABS
Special Cable Twisted-pair cable; RS232 communication
Generally, the standard is 5m*2, optional 10m*2
Pipe Condition Pipe Material Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, fiberglass product, liner is allowed.
Pipe Diameter DN 15—6000mm
Straight length pipe Transducer installation should be satisfied: upstream 10D, downstream 5D,
30D from the pump.
Measuring Medium Type of Liquid Water ; Ultra-pure liquids; Solvents and other liquids
Temperature Standard Transducer: -30–90℃; High-temperature transducer: -30–160℃
Turbidity under 10000ppm and less bubble
Flow rate 0–±10m/s
Flow Direction Bidirectional (forward and reverse flow)
Working Environment Temperature Main Unit: -20–60℃
Flow transducer: -30–160℃;
Temperature transducer: according to the customer’s demands.
Humidity Main Unit: 85% RH
Power Supply 3 built-in 1.2V rechargeable Ni-MH batteries with a capacity of 2000mAH. Each full charge can last for more than 12 hours. Use AC90~260V power adapter to achieve uninterrupted measurement.
Power consumption 1.5W

Sensor parameters

Clamp-on sensor type Model Protection Class Measuring Pipe Size Medium Temperature
Standard TS-2 IP68 DN15~DN100 -30~90℃
TM-1 IP68 DN50~DN700 -30~90℃
TL-1 IP68 DN300~DN6000 -30~90℃
High Temperature Standard TS-2-HT IP68 DN15~DN100 -30~160℃
TM-1-HT IP68 DN50~DN700 -30~160℃
TL-1-HT IP68 DN300~DN6000 -30~160℃
Mounting Bracket HS IP68 DN15~DN100 -30~90℃
HN IP68 DN50~DN700 -30~90℃
EB-1 IP68 DN300~DN6000 -30~90℃
High Temperature Mounting Bracket HS-HT IP68 DN15~DN100 -30~160℃
HM-HT IP68 DN50~DN700 -30~160℃
EB-1-HT IP68 DN300~DN6000 -30~160℃

High Temperature Standard clamp-on ultrasonic sensor Mounting Bracket and High Temperature Mounting BracketsStandard clamp-on ultrasonic sensor

Get Ultrasonic Flow meter Selection and Quotation

Our Sino-Inst handheld ultrasonic flowmeters have a wider range of applications and enables portable pipeline flow measurement at low cost. In-stock products, faster shipping!

Contact Form Demo (#3)
Products Categories
Get A Free Quote
Contact Form Demo (#3)

Handheld Ultrasonic Flow Meter Application

 

Handheld ultrasonic flow meters are widely used to measure pure single liquids such as tap water, air conditioning water, and heating hot water. Please note that the pipe must be running full of liquid, with at least 10D of straight pipe upstream and 5D downstream. Rigid pipes such as carbon steel, stainless steel, cast iron, copper and PVC are suitable.
The handheld ultrasonic flowmeter can be used for production monitoring, checking installed flow meters and water meters, temporary detection, flow inspection, heating network balance debugging, and energy saving monitoring. It is an essential tool for timely flow detection.

Typical media and applications (full liquid pipelines only):

  1. Water (hot water, cooling water, drinking water, sea water, etc.);
  2. Petroleum products;
  3. Chemicals, including alcohol, acid, etc.;
  4. Beverage, food and pharmaceutical processors;
  5. Treated wastewater with low solids content (below 10,000 ppm);
  6. Leak checks on water mains, by comparing flow at two points on the same line;
  7. Pipelines at pump stations, power plants, water supply networks and drainage systems.

Application Cases

Hot-water line at 150°C, India
A distributor’s end user needed portable flow checks on a hot-water line running at 150°C. Standard transducers are rated up to 90°C, so we specified the high-temperature clamp-on set (TS-2-HT / TM-1-HT), rated from -30 to 160°C, with the same handheld main unit.

Stand-in meter during repairs, Uruguay
An engineering company had to send its installed flow meter away for repair and needed something to cover the gap. The lines were DN32–DN100, carrying water and a 20% propylene glycol solution. One handheld meter with TS-2 small-pipe transducers covers that whole size range. Readings are logged in the meter and can be downloaded over RS232.

Handheld Ultrasonic Flow Meter - Portable and Clamp On Detail Display
More Detail

Are ultrasonic flow meters accurate?

Ultrasonic flowmeters offer high measurement accuracy, typically reaching 1%. They are virtually unaffected by the various parameters of the medium being measured. They are particularly effective at solving flow measurement challenges for media that are difficult for other instruments to handle—such as highly corrosive, non-conductive, or radioactive substances, as well as flammable or explosive materials.

So, what causes inaccuracies in ultrasonic flowmeter measurements? The primary causes of measurement errors include:

  • Uniformity of the pipe material;
  • Presence of impurities or air bubbles in the medium;
  • Adequacy of straight pipe sections upstream and downstream;
  • Quality of the coupling agent used during sensor installation (ensuring perfect contact);
  • Correct selection of the sensor installation location.

How does a portable ultrasonic flow meter work?

The core operating principle of the portable ultrasonic flow meter is the transit-time method: it measures the time difference caused by varying propagation speeds during forward and reverse transmission to calculate the velocity of the fluid being measured.

A signal emitted by one transducer travels through the pipe wall, the medium, and the opposite pipe wall before being received by the other transducer; simultaneously, the second transducer emits a signal that is received by the first. Due to the influence of the fluid’s flow velocity, a time difference (Δt) arises between the two signals. Mathematical derivation establishes the conversion relationship between flow velocity (V) and time difference (Δt) as V = (C²/2L) × Δt, from which the flow rate (Q) can be determined.

What is the difference between ultrasonic and magnetic flow meter?

Electromagnetic flowmeter and ultrasonic flowmeter are two types of flow meters, which are mainly suitable for measuring the volume flow of fluid in pipelines.

The principles are different:
Electromagnetic flowmeters use Faraday’s electromagnetic induction principle to measure the volume flow of conductive liquids; ultrasonic flowmeters calculate flow velocity and flow rate from the difference in transit time of ultrasonic signals travelling with and against the flow.

The scope of application is different:
Electromagnetic flowmeter is suitable for liquids with good conductivity, such as water, acid, alkali, etc., and has certain requirements for the conductivity of the liquid. Generally, the conductivity of the medium to be measured is required to be no less than 5uS/cm;
Ultrasonic flow meters are suitable for many types of liquids, including drinking water, food, chemicals, etc., and do not require high conductivity of the liquid.

Measurement accuracy varies:
The measurement accuracy of electromagnetic flowmeter is usually 0.5%;
The measurement accuracy of ultrasonic flowmeter is generally 1%.

Different anti-interference capabilities:
The electromagnetic flowmeter has shielded excitation coils during the production process and has good resistance to magnetic field interference;
Clamp-on ultrasonic flow meters are more sensitive to installation conditions, such as straight pipe length, pipe condition and couplant quality.

Installation methods are different:
Electromagnetic flowmeters are installed in-line, so the pipe has to be cut and flanged, and the location should avoid strong magnetic fields;
Clamp-on ultrasonic flow meters are strapped to the outside of the pipe, so no pipe cutting is needed and nothing touches the liquid.

Prices and features vary:
The price of electromagnetic flowmeter is proportional to the pipe diameter, and it has the characteristics of high precision and high repeatability;
Ultrasonic flow meters are relatively low-priced and feature no pressure loss and non-contact measurement.

Related Products

Related News

Water and wastewater professionals rely on precise flow measurement to ensure process operation and regulatory compliance. Selecting the appropriate flow […]

In the field of pipeline network flow monitoring, traditional insertion-type and in-line flow meters require pipe-cutting work, which can easily […]

Ultrasonic flow meter is a common tool for measuring flow. It has high accuracy and non-contact design, which makes it […]

Clamp-on and inline flow meters are the two main installation types for flow measurement, falling into non-intrusive and intrusive measurement […]

As a prime example of non-invasive flow measurement technology, portable ultrasonic flow meters have found increasingly widespread application in fields […]

As a non-intrusive flow measurement technology, clamp-on ultrasonic flowmeters enable online monitoring of fluid flow by clamping transducers onto the […]

Scroll to Top

Get A Free Quote Now !

Contact Form Demo (#3)